- 1
Upload your IFC or GLB model to the survey (see “Upload your first point cloud & BIM”). The model needs to be georeferenced or aligned with the point cloud.
- 2
Under BIM Models in the Scene panel, choose Overlay to see the model on top of the scan. Use the opacity control to fade it in and out.
The BIM model overlaid on the point cloud - 3
Choose Split to see the scan and the model side by side.
Split view: scan on the left, model on the right - 4
To check one element, select it in the BIM object tree. The point cloud is cropped to that element. (UI may differ)
- 5
Start Detect, then pick a tolerance in Tolerance Configuration and click Run Detection. (UI may differ)
- LOD 300
- Medium tolerance, about 20 mm
- LOD 400
- Strict, about 5 mm
- LOD 500
- Field verified, about 1 mm
Tolerance Configuration - 6
Detection runs in the background, so the viewer stays responsive.
Running deviation detection - 7
Elements within tolerance turn green. Elements outside it turn red, with a note on the kind of deviation: shifted, rotated, the wrong size, or missing.
A deviation flagged in red on the model - 8
Click a flagged deviation to raise an issue. The element ID, its 3D position and a screenshot are filled in for you.
Good to know
- Organization Admins and Supervisors can set tolerances and run detection. Members can open existing results.
- Pick the tolerance that matches the stage of work and your specification.
- Run detection soon after each scan of an area, while deviations can still be fixed cheaply.
Common problems and fixes
Nearly everything shows as deviated
The model and the scan are probably not aligned. Check both use the same coordinate system, then use Overlay to confirm they sit on top of each other before you run detection.
An element shows as missing but it was built
The scan may not have captured it, for example because it was hidden behind other work. Check the spot in the point cloud or a 360° image before you raise an issue.
I can’t run detection
Setting tolerances and running detection needs an Organization Admin or Supervisor role.
My model won’t load
Use IFC or GLB, exporting from your authoring tool if needed, and upload it to the same survey as the scan.
What to do next
Issues raised from deviations land on the board: see Mark & track issues in SpatialSense. To measure a single gap between scan and model, see Measure on the point cloud in SpatialSense.